• KAFM
  • Contact us
  • E-Submission
ABOUT
ARTICLE CATEGORY
BROWSE ARTICLES
AUTHOR INFORMATION

Page Path

1
results for

"Clothing"

Filter

Article category

Keywords

Publication year

"Clothing"

Original Article
Background

According to the current guidelines for blood pressure monitoring, clinicians are recommended to measure blood pressure by completely exposing the upper arm. However, it is a common practice that blood pressure is measured with the cuff placed over the sleeve or with the sleeve rolled up. We therefore conducted this study to examine whether there are any differences in blood pressure measurements among the three different settings: the sleeve group, the rolled sleeve group, and the bare arm group.

Methods

We conducted the current study in 141 male and female adult patients who visited our clinical department. In these patients, we took repeatedly blood pressure measurements using the same automatic oscillometric device on three different settings. Then, we analyzed the results with the use of randomized block design analysis of variance.

Results

The mean values of systolic blood pressure (SBP) between the first reading and those of the second reading were 128.5 ± 10.6 mm Hg in the sleeve group, 128.3 ± 10.8 mm Hg in the rolled sleeve group, and 128.3 ± 10.7 mm Hg in the bare arm group. These results indicate that there were no significant differences among the three groups (P = 0.32). In addition, the mean values of diastolic blood pressure (DBP) between the first reading and those of the second reading were 80.7 ± 6.1 mm Hg in the sleeve group, 80.7 ± 6.1 mm Hg in the rolled sleeve group, and 80.6 ± 5.9 mm Hg in the bare arm group. These results indicate that there were no significant differences among the three groups (P = 0.77). In addition, based on the age, sex, past or current history of hypertension or diabetes mellitus, the thickness of sleeve, weight, a drinking history, and a smoking history, there were no significant differences in SBP and DBP among the three groups.

Conclusion

There were no significant differences in blood pressure measurements between the three different settings (the sleeve group, the rolled sleeve group, and the bare arm group).

Citations

Citations to this article as recorded by  
  • Comparison of blood pressure measurements on the bare and sleeved arms – what does it uncover?
    Rotem Tal-Ben Ishay, Adi Leiba, Vladimir Rappoprt, Avital Angel-Korman, Zeev Katzir
    Blood Pressure Monitoring.2024; 29(1): 31.     CrossRef
  • A Survey on Blood Pressure Measurement Technologies: Addressing Potential Sources of Bias
    Seyedeh Somayyeh Mousavi, Matthew A. Reyna, Gari D. Clifford, Reza Sameni
    Sensors.2024; 24(6): 1730.     CrossRef
  • The Effect of Clothes on Blood Pressure Measurement in Normotensive and Hypertensive Subjects in a Real-Life Setting
    Edwin Castillo Velarde, Jorge Roca-Sánchez-Moreno, Alison Núñez Muñoz, Alessandra Guillen Rivera, Mary Hidalgo Babilonia, Jherson García Meneses, Lisseth Mamani Turpo, Willian Cepeda Horna
    Kidney and Blood Pressure Research.2024; : 1.     CrossRef
  • The Differences in the Measurements of Blood Pressure over Bare Versus Sleeved Arm with Routine Clothing in Outdoor Patients
    Abdul Khalid, Rubina Rafique, Muhammad Arshad, Mazhar Hamdani, M. Naseem Sheikh, Sabahat Zahra
    Journal of Pakistan Society of Internal Medicine.2023; 4(2): 120.     CrossRef
  • Sources of automatic office blood pressure measurement error: a systematic review
    Jian Liu, Yumin Li, Jianqing Li, Dingchang Zheng, Chengyu Liu
    Physiological Measurement.2022; 43(9): 09TR02.     CrossRef
  • No effect of sleeved arms on the accuracy of blood pressure measurement
    Ya Li, Yi Li, Fang Li, Demin Liu, Yanan Zhang, Xiaoran Cui, Wei Cui
    Internal Medicine Journal.2021; 51(12): 2087.     CrossRef
  • Blood pressure measurements on a bare arm, over a sleeve or below a rolled-up sleeve: a systematic review and meta-analysis
    David Seguret, Danaé Gamelon, Caroline Dourmap, Olivier Steichen
    Journal of Hypertension.2020; 38(9): 1650.     CrossRef
  • The Reliability of Noninvasive Blood Pressure Measurement Through Layers of Autumn/Winter Clothing: A Prospective Study
    Przemysław Wołoszyn, Ignacy Baumberg, David Baker
    Wilderness & Environmental Medicine.2019; 30(3): 227.     CrossRef
  • Effect of garment on the arm under the auscultatory manometer cuff among primigravidae
    Ganapathy Thilagavathy, Samia Saud Al Furaikh
    Journal of Dr. NTR University of Health Sciences.2018; 7(2): 129.     CrossRef
  • 6,322 View
  • 40 Download
  • 9 Crossref
TOP